You are viewing the documentation for an older COMSOL version. The latest version is available here.
Impressed Current Surface
Use the Impressed Current Surface node to control the potential difference between a sense s, sense (V) and a reference s, ref (V) potential, which both are defined globally.
The desired potential difference Eimpr (V) is achieved by applying a electrolyte potential constraint on the boundary selection of the impressed current surface, using an added global electrolyte potential dependent variable left to “float” in order to fulfill the control condition.
The node is exclusive and is applicable to external boundaries to Electrolyte domains.
The node is active if Enable Cathodic Protection Features check box is enabled at the interface node.
Constraint Settings
To display this section, click the Show More Options button () and select Advanced Physics Options in the Show More Options dialog box.
Corrosion Protection of a Ship Hull: Application Library path Corrosion_Module/Cathodic_Protection/ship_hull