Use Sequence Member nodes (
) to define the individual events in the
Event Sequence. Each
Sequence Member will be activated in turn. Right-click an
Event Sequence node to add
Sequence Member subnodes.
The Discrete state name can be used in other physics features to activate settings while that state is active.
From the End condition list, choose
Expression (the default) so that each step runs until a certain
End condition expression (>0) becomes positive, or choose
Duration to make it continue for a fixed
Duration (default: 1 s). The
Use consistent initialization option is the same as for
Explicit Event.
In the table under Variables, enter any additional global dependent variable name for which the value should be changed when an event occurs. In the
Expression column, enter the corresponding reinitialization expression for each variable.