Non-Darcian flow defines a nonlinear relationship using Equation 7-12 and the pressure-velocity relationship
|
•
|
From density and porosity (default), uses the formulation of Equation 7-12
|
•
|
Linearized storage, where the following linear equation is used to define the storage:
|
•
|
User defined to directly specify the storage coefficient S
|
|
•
|
Highly conductive fracture represents a fracture filled with a highly permeable material.
|
•
|
Thin conducting barrier represents a fracture that is filled with a low permeable material and therefore acts as a barrier for the flow which adds a jump in the pressure across the boundary:
|
Note that the option to specify the Fracture Model is only available for the Fracture feature within the Darcy’s Law interface.
|
Flow in a Fractured Reservoir: Application Library path Subsurface_Flow_Module/Fluid_Flow/fractured_reservoir_flow
|