Face Load
Add a Face Load to boundaries (for the Plate interface add it to domains), to use it as a pressure or tangential force acting on a surface. The loads are defined in the given coordinate system.
Through-Thickness Location
Select a surface — Top Surface, Midsurface, or Bottom Surface. The default is that the load is applied at the midsurface. The effect of using another surface than the midsurface is twofold:
To place the load at another distance from the midsurface, select the Offset check box, and enter a value for the offset, zoffset.
If the material model is Section Stiffness, there may physically not be a well-defined top and bottom surface. If the load is applied at such a surface, the thickness value used to compute the load is taken from the settings in the Thickness and Offset node.
Force
Select a Load typeForce per unit area, Total force, or Pressure.
Table 5-17:  
FA
Ftot
After selecting a Load type, the Load list normally only contains User defined. When combining with another physics interface, it is also possible to choose a predefined load from this list.
Moment
Enter values or expressions for the components of the moment face load MA.
You can add the Phase subnode to specify the phase of this load in a frequency domain analysis.
Location in User Interface
Context Menus
Ribbon
Physics tab with Shell or Membrane selected:
Physics tab with Plate selected: