Linearized Buckling Analysis
A linearized buckling analysis can be used for estimating the critical load at which a structure becomes unstable. This is a predefined study type that consists of two study steps: An initial step in which a unit load is applied to the structure, and a second step in which an eigenvalue problem is solved for the critical buckling load.
COMSOL reports a critical load factor, λ,which is the multiplier to the initial load at which the structure becomes unstable. The corresponding eigenmode is the shape of the structure in its buckled state.
The level of the initial load used is immaterial since a linear problem is solved. If the initial load actually was larger than the buckling load, then the critical value of λ is smaller than 1. It is also possible that the computed value of λ is negative. This signifies that a reversed load will give the critical case.
The buckling computed buckling modes can be used to provide an initial imperfection for a subsequent nonlinear buckling analysis,
Bracket — Linear Buckling Analysis: Application Library path Structural_Mechanics_Module/Tutorials/bracket_linear_buckling
Linear Buckling Analysis of a Truss Tower: Application Library path Structural_Mechanics_Module/Buckling_and_Wrinkling/truss_tower_buckling