Mass Source
The Mass Source node adds a mass source Qm, which appears on the right-hand side of the Darcy’s Law equation (Equation 4-6).
(4-10)
For The Fracture Flow Interface — which is available for the Subsurface Flow Module and the Porous Media Flow Module — the mass source is applicable to the right-hand side of Equation 4-22 (where it is multiplied with the fracture thickness).
Mass Source
Enter a value or expression for the Mass source Qm (SI unit: kg/(m3·s)). The default is 0 kg/(m3·s).