Outlet
The Outlet node defines an edge or point where fluid leaves the gap.
Outlet Settings
Select an Outlet conditionZero pressure (the default), Pressure, Normal outflow velocity, or Outflow. When the Cavitation check box is selected for the physics interface (see Cavitation), Starvation is also available.
For Zero pressure, pf = 0 applies on the boundary, edge, or point.
For Pressure, enter a Pressure pf0 (SI unit: Pa) to impose pf = pf0 on the boundary, edge, or point. The default is 0 Pa. If the reference pressure pref, defined at the physics interface level is 0, pf0 is the absolute pressure. Otherwise, pf0 is the relative pressure.
For Normal outflow velocity, enter a Normal outflow velocity U0 (SI unit: m/s). The default is 0 m/s.
For Outflow, the fluid is allowed to leave the gap without explicitly imposing a value of pressure or velocity.
For Starvation, enter a value for the Fluid fraction θ0 (dimensionless). The default is 0.6.