Inlet
Use the Inlet node to define an edge or point where fluid enters the gap.
Inlet Settings
Select an Inlet conditionZero pressure (the default), Pressure, or Normal inflow velocity. When the Cavitation check box is selected for the physics interface (see Cavitation), Starvation is also available.
For Zero pressure pf = 0 applies on the boundary, edge, or point.
For Pressure enter a Pressure pf0 (SI unit: Pa) to impose pf = pf0 on the boundary, edge, or point. The default is 0 Pa. If the reference pressure pref, defined at the physics interface level is 0, pf0 is the absolute pressure. Otherwise, pf0 is the relative pressure.
For Normal inflow velocity enter a Normal inflow velocity U0 (SI unit: m/s). The default is 0 m/s.
For Starvation enter a value for the Fluid fraction θ0 (dimensionless). The default is 0.6.