Enter the Pressure p0 (SI unit: Pa) at the boundary. The default is 0 Pa. Enter a relative pressure value in p0 (SI unit: Pa). Or if the reference pressure pref defined at the physics interface level is equal to 0 Pa, enter an absolute pressure in p0.
|
•
|
Select the Normal flow check box to change the no tangential stress condition to a no tangential velocity condition. This forces the flow to exit (or enter) the domain perpendicularly to the outlet boundary.
|
•
|
The Suppress backflow check box is selected by default. This option adjusts the outlet pressure in order to reduce the amount of fluid entering the domain through the boundary.
|
•
|
•
|
For Velocity field specify that the velocity at the boundary is equal to a given j0 (SI unit: m/s) and enter the components in the matrix:
|