Coupled-Line Bandpass Filter
Introduction
A narrow-band bandpass filter can be realized using coupled microstrip lines. Each microstrip line piece is approximately a half wavelength long at the bandpass frequency. The bandpass performance of such a filter is much better than that of a single-section coupled-line filter.
Figure 1: Layout of a coupled-line bandpass filter. It is composed of five sections of microstrip lines.
Model Definition
The form of the coupled microstrip line filter being modeled is shown in Figure 1. The layout was designed based upon Ref. 1 to have a center frequency at 3.6 GHz, and is composed of five sections of microstrip lines. The objective of this design is to have better out-of-band rejection compared to a design with fewer cascading strips. The length of each line section is tuned such that the impedance of the filter is 50 Ω. The ports are assumed to be coupled to a 50 Ω microstrip line that is not modeled.
The microstrip lines are each modeled as perfect electric conductor (PEC) surfaces on a 0.020 inch thick dielectric substrate, with another PEC surface below that acts as the ground plane. The entire modeling domain is bounded by PEC boundaries that represent the packaging.
Two rectangular surfaces are used to model the ports. These small rectangular surfaces that bridge between two PEC surfaces represent a connection to a 50 Ω transmission line. The device is excited at one port and S11 and S21 are monitored around the bandpass frequency. The model is shown in Figure 2.
Due to the thin gap between the microstrip lines, some care must be taken during the meshing. As a general rule of thumb, at least five elements per wavelength in each material are sufficient, and the elements should have an aspect ratio of approximately unity. However, this design also has a small gap between two of the microstrip lines. This leads to very small elements in this gap region when using the default mesh settings, and the solution time is quite long. An alternative approach is to modify the mesh settings such that the elements in the gap region have a higher aspect ratio. Despite this, the solution agrees well with a finer mesh, and uses less memory.
Figure 2: The model of the coupled-line bandpass filter. The color range is scaled to emphasize the resonance on the microstrip lines.
Results and Discussion
Figure 3 shows S11 and S21 around the bandpass frequency. Excellent out of band rejection is observed. The coupling gaps can further be adjusted for frequency response optimization.
Figure 3: Frequency response of the coupled-line bandpass filter. The bandpass performance of the filter is much better than that of a single-section coupled-line filter.
Reference
1. D.M. Pozar, Microwave Engineering, John Wiley & Sons, 1998
Application Library path: RF_Module/Filters/coupled_line_filter
Modeling Instructions
From the File menu, choose New.
New
In the New window, click  Model Wizard.
Model Wizard
1
In the Model Wizard window, click  3D.
2
In the Select Physics tree, select Radio Frequency>Electromagnetic Waves, Frequency Domain (emw).
3
Click Add.
4
Click  Study.
5
In the Select Study tree, select General Studies>Frequency Domain.
6
Study 1
Step 1: Frequency Domain
1
In the Model Builder window, under Study 1 click Step 1: Frequency Domain.
2
In the Settings window for Frequency Domain, locate the Study Settings section.
3
Click  Range.
4
In the Range dialog box, type 3[GHz] in the Start text field.
5
In the Step text field, type 50[MHz].
6
In the Stop text field, type 4.2[GHz].
7
Click Replace.
Global Definitions
Define some parameters that are useful when setting up the mesh and the study.
Parameters 1
1
In the Model Builder window, under Global Definitions click Parameters 1.
2
In the Settings window for Parameters, locate the Parameters section.
3
Here mil refers to the unit milliinch, that is 1 mil = 0.0254 mm.
Geometry 1
First, create a block for the substrate.
Substrate
1
In the Geometry toolbar, click  Block.
2
In the Settings window for Block, type Substrate in the Label text field.
3
Locate the Size and Shape section. In the Width text field, type l_line/2.
4
In the Depth text field, type l_line*2.2.
5
In the Height text field, type thickness.
6
Locate the Position section. From the Base list, choose Center.
Then, add a block for the metal package enclosing the substrate.
Enclosure
1
In the Geometry toolbar, click  Block.
2
In the Settings window for Block, type Enclosure in the Label text field.
3
Locate the Size and Shape section. In the Width text field, type l_line/2.
4
In the Depth text field, type l_line*2.4.
5
In the Height text field, type l_line/5.
6
Locate the Position section. From the Base list, choose Center.
7
In the z text field, type l_line/10-thickness/2.
8
Click  Build All Objects.
9
Click the  Wireframe Rendering button in the Graphics toolbar.
Add a work plane on the substrate to create the microstrip lines.
Work Plane 1 (wp1)
1
In the Geometry toolbar, click  Work Plane.
2
In the Settings window for Work Plane, locate the Plane Definition section.
3
In the z-coordinate text field, type thickness/2.
4
Click  Show Work Plane.
Work Plane 1 (wp1)>Plane Geometry
Create a rectangle for the microstrip line connected to Lumped port 1.
Work Plane 1 (wp1)>Rectangle 1 (r1)
1
In the Work Plane toolbar, click  Rectangle.
2
Click the  Zoom Extents button in the Graphics toolbar.
3
In the Settings window for Rectangle, locate the Size and Shape section.
4
In the Width text field, type w_line.
5
In the Height text field, type l_line*0.6.
6
Locate the Position section. From the Base list, choose Center.
7
In the xw text field, type -w_line*2-gap*1.07.
8
In the yw text field, type -l_line*0.8.
Work Plane 1 (wp1)>Plane Geometry
Then, add a rectangle next to the first microstrip line. There is a very thin gap between two microstrip lines.
Work Plane 1 (wp1)>Rectangle 2 (r2)
1
In the Work Plane toolbar, click  Rectangle.
2
In the Settings window for Rectangle, locate the Size and Shape section.
3
In the Width text field, type w_line.
4
In the Height text field, type l_line.
5
Locate the Position section. From the Base list, choose Center.
6
In the xw text field, type -w_line-gap.
7
In the yw text field, type -l_line/2.
Work Plane 1 (wp1)>Plane Geometry
Generate another pair of microstrip lines with a thin gap at the other side of the substrate by rotating the above two rectangles 180 degrees. Keep the input objects.
Work Plane 1 (wp1)>Rotate 1 (rot1)
1
In the Work Plane toolbar, click  Transforms and choose Rotate.
2
Click in the Graphics window and then press Ctrl+A to select both objects.
3
In the Settings window for Rotate, locate the Input section.
4
Select the Keep input objects check box.
5
Locate the Rotation section. In the Angle text field, type 180.
Work Plane 1 (wp1)>Plane Geometry
Finish the layout on the substrate by adding the last piece of the microstrip lines on the center of the substrate.
Work Plane 1 (wp1)>Rectangle 3 (r3)
1
In the Work Plane toolbar, click  Rectangle.
2
In the Settings window for Rectangle, locate the Size and Shape section.
3
In the Width text field, type w_line.
4
In the Height text field, type l_line.
5
Locate the Position section. From the Base list, choose Center.
6
Click  Build Selected.
Add a work plane to define boundaries for the lumped ports.
Work Plane 2 (wp2)
1
In the Model Builder window, right-click Geometry 1 and choose Work Plane.
2
In the Settings window for Work Plane, locate the Plane Definition section.
3
From the Plane type list, choose Face parallel.
4
On the object blk1, select Boundary 3 only.
Work Plane 2 (wp2)>Plane Geometry
In the Model Builder window, click Plane Geometry.
Create a rectangle for the first lumped port.
Work Plane 2 (wp2)>Rectangle 1 (r1)
1
In the Work Plane toolbar, click  Rectangle.
2
Click the  Zoom Extents button in the Graphics toolbar.
3
In the Settings window for Rectangle, locate the Size and Shape section.
4
In the Width text field, type thickness.
5
In the Height text field, type w_line.
6
Locate the Position section. From the Base list, choose Center.
7
In the yw text field, type w_line*2+gap*1.07.
Then, rotate the above rectangle to create the second lumped port.
Rotate 1 (rot1)
1
In the Model Builder window, right-click Geometry 1 and choose Transforms>Rotate.
2
3
In the Settings window for Rotate, locate the Input section.
4
Select the Keep input objects check box.
5
Locate the Rotation section. In the Angle text field, type 180.
6
Click  Build All Objects.
Definitions
Create a set of selections for use before setting up the physics.
Substrate
1
In the Definitions toolbar, click  Explicit.
2
In the Settings window for Explicit, type Substrate in the Label text field.
3
Add a selection for the microstrip line traces.
Microstrip line
1
In the Definitions toolbar, click  Explicit.
2
In the Settings window for Explicit, type Microstrip line in the Label text field.
3
Locate the Input Entities section. From the Geometric entity level list, choose Boundary.
4
View 1
Hide three boundaries to get a better view of the interior parts when setting up the physics.
Hide for Physics 1
1
In the Model Builder window, right-click View 1 and choose Hide for Physics.
2
In the Settings window for Hide for Physics, locate the Geometric Entity Selection section.
3
From the Geometric entity level list, choose Boundary.
4
To see the objects in selections, make sure that Show Objects in Selection is turned on. The button is located at the upper-left corner in the Hide Geometric Entities settings window.
Electromagnetic Waves, Frequency Domain (emw)
Now set up the physics. The default boundary condition is Perfect Electric Conductor, which applies to all exterior boundaries. Also, assign a perfect electric conductor condition on the interior boundary of the microstrip lines. Use the selection for the microstrip line boundaries that you defined earlier.
Perfect Electric Conductor 2
1
In the Model Builder window, under Component 1 (comp1) right-click Electromagnetic Waves, Frequency Domain (emw) and choose Perfect Electric Conductor.
2
In the Settings window for Perfect Electric Conductor, locate the Boundary Selection section.
3
From the Selection list, choose Microstrip line.
Lumped Port 1
1
In the Physics toolbar, click  Boundaries and choose Lumped Port.
2
For the first port, wave excitation is on by default.
Lumped Port 2
1
In the Physics toolbar, click  Boundaries and choose Lumped Port.
2
Materials
Next, assign material properties on the model. Begin by specifying air for all domains.
Add Material
1
In the Home toolbar, click  Add Material to open the Add Material window.
2
Go to the Add Material window.
3
4
Click Add to Component in the window toolbar.
5
In the Home toolbar, click  Add Material to close the Add Material window.
Materials
Override the substrate with a dielectric material of εr = 3.38.
Substrate
1
In the Model Builder window, under Component 1 (comp1) right-click Materials and choose Blank Material.
2
In the Settings window for Material, type Substrate in the Label text field.
3
Locate the Geometric Entity Selection section. From the Selection list, choose Substrate.
4
Locate the Material Contents section. In the table, enter the following settings:
Mesh 1
In the Model Builder window, under Component 1 (comp1) right-click Mesh 1 and choose Build All.
Study 1
In the Home toolbar, click  Compute.
Results
Electric Field (emw)
The default plot shows the distribution of the norm of the electric field. Show that only on the xy-plane.
1
In the Settings window for 3D Plot Group, locate the Data section.
2
From the Parameter value (freq (GHz)) list, choose 3.55.
Multislice
1
In the Model Builder window, expand the Electric Field (emw) node, then click Multislice.
2
In the Settings window for Multislice, locate the Multiplane Data section.
3
Find the X-planes subsection. In the Planes text field, type 0.
4
Find the Y-planes subsection. In the Planes text field, type 0.
5
Find the Z-planes subsection. From the Entry method list, choose Coordinates.
6
In the Coordinates text field, type 0.
7
In the Electric Field (emw) toolbar, click  Plot.
8
Click the  Zoom Extents button in the Graphics toolbar.
The microstrip line in the middle of the substrate shows the resonance at the selected frequency.
S-parameter (emw)
Smith Plot (emw)
Analyze the same model with a Frequency Domain Modal method. When a device presents resonances, the Frequency Domain Modal method combined with an Eigenfrequency analysis provides a faster solution time.
Electromagnetic Waves, Frequency Domain (emw)
Lumped Port 1
1
In the Model Builder window, under Component 1 (comp1)>Electromagnetic Waves, Frequency Domain (emw) click Lumped Port 1.
2
In the Settings window for Lumped Port, locate the Boundary Selection section.
3
Click  Create Selection.
4
In the Create Selection dialog box, Create a set of selections for use in the study settings.
5
type Lumped port 1 in the Selection name text field.
6
Lumped Port 2
1
In the Model Builder window, click Lumped Port 2.
2
In the Settings window for Lumped Port, locate the Boundary Selection section.
3
Click  Create Selection.
4
In the Create Selection dialog box, type Lumped port 2 in the Selection name text field.
5
Add Study
1
In the Home toolbar, click  Add Study to open the Add Study window.
2
Go to the Add Study window.
3
Find the Studies subsection. In the Select Study tree, select Preset Studies for Selected Physics Interfaces>Frequency Domain, Modal.
4
Click Add Study in the window toolbar.
5
In the Home toolbar, click  Add Study to close the Add Study window.
Study 2
Step 1: Eigenfrequency
1
In the Settings window for Eigenfrequency, locate the Study Settings section.
2
In the Search for eigenfrequencies around text field, type 3[GHz].
Step 2: Frequency Domain, Modal
1
In the Model Builder window, click Step 2: Frequency Domain, Modal.
2
In the Settings window for Frequency Domain, Modal, locate the Study Settings section.
3
In the Frequencies text field, type range(3[GHz],50[MHz]/50,4.2[GHz]).
With a 50 times finer frequency step, the solutions will increase the model file size tremendously when it is saved. When only S-parameters are of interest, a common theme in most passive RF and microwave device designs, it is not necessary to store all of the field solutions. By selecting the Store fields in output check box in the Values of Dependent Variables section, we can control the part of the model on which the computed solution is saved. We only add the selection containing these boundaries where the S-parameters are calculated. The lumped port size is typically very small compared to the entire modeling domain, and the saved file size with the finer frequency step is more or less that of the regular discrete frequency sweep model when only the solutions on the port boundaries are stored.
4
Click to expand the Values of Dependent Variables section. Find the Store fields in output subsection. From the Settings list, choose For selections.
5
Under Selections, click  Add.
6
In the Add dialog box, in the Selections list, choose Lumped port 1 and Lumped port 2.
7
8
In the Home toolbar, click  Compute.
Results
Electric Field (emw) 1
Since the results are stored only on the lumped port boundaries, this default E-field norm plot does not provide useful information.
1
Right-click Results>Electric Field (emw) 1 and choose Delete.
Generate all S-parameters from each analysis on the same plot and compare them to each other.
S-parameter (emw) 1
1
In the Model Builder window, click S-parameter (emw) 1.
2
In the Settings window for 1D Plot Group, click to expand the Title section.
3
From the Title type list, choose Manual.
4
In the Title text area, type S-parameter Comparison between Frequency Domain Modal and Discrete Sweep.
5
Locate the Legend section. From the Position list, choose Lower right.
Global 2
1
In the Model Builder window, expand the S-parameter (emw) 1 node.
2
Right-click Results>S-parameter (emw) 1>Global 1 and choose Duplicate.
3
In the Settings window for Global, locate the Data section.
4
From the Dataset list, choose Study 1/Solution 1 (sol1).
5
Click to expand the Coloring and Style section. Find the Line style subsection. From the Line list, choose Dotted.
6
Find the Line markers subsection. From the Marker list, choose Cycle.
7
From the Positioning list, choose In data points.
Global 1
1
In the Model Builder window, click Global 1.
2
In the Settings window for Global, locate the y-Axis Data section.
3
4
In the S-parameter (emw) 1 toolbar, click  Plot.
Compare the resulting plots with that shown in Figure 3.
Smith Plot (emw) 1
Compare the solution time between two studies.
Touchstone 1
1
In the Results toolbar, click  Data and choose Touchstone.
2
In the Settings window for Touchstone, locate the Output section.
3
In the Filename text field, type coupled_line_filter_touchstone.s2p.
4
From the Parameter format list, choose Magnitude in dB and angle.
5
Click  Export.
Warning 1
Review the warning. Since a port sweep is not performed, the solution is incomplete to generate a full S-parameter matrix. The Touchstone export assumes the simulation model is a reciprocal network and creates a symmetric matrix.