PDF

Dielectric Shielding Comparison
Introduction
The dielectric shielding boundary condition is meant to approximate a thin layer of material with high relative permittivity compared to its surroundings. This boundary condition is available for electrostatic field modeling. This example compares the dielectric shielding boundary condition to a full-fidelity model and discusses the range of applicability of this boundary condition.
Figure 1: A two-dimensional parallel plate capacitor in free space. A thin-walled circular inclusion between the plates distorts the electric field.
Model Definition
The situation being modeled is shown in Figure 1. Two parallel plates in free space (relative permittivity, ε= 1) have a voltage difference applied to them, forming a capacitor. Between these plates there is a 1 cm outer diameter circular inclusion with a wall thickness of 1mm. The walls are made of a high dielectric (ε= 20) material.
The walls of this inclusion are modeled two ways, first using a full fidelity model that includes the thickness of the walls, and also using the dielectric shielding boundary condition. The inside of the inclusion has the same properties as free space. The two models are separate, but are being modeled simultaneously for comparison.
The location of the dielectric shielding condition is at the centerline, midway between the inner and outer radii of the full fidelity model. Note that, when using the dielectric shielding condition, the total volume of the surrounding material is slightly larger, since the thickness of the wall is not being explicitly modeled.
Results and Discussion
The electric field and isolines of the voltage is plotted in Figure 2. The field lines can be observed to deform toward the inclusion. The solutions for the full fidelity and electric shielding model agree well.
Figure 2: Isolines of the voltage field, and streamlines of the electric field are plotted. The lines are colored according to the strength of the electric field, and the background gray-scale plot is of the electric field. The full fidelity (left) and dielectric shielding (right) solutions are almost identical.
The dielectric shielding boundary condition can be used in cases where the thickness of the boundary being approximated is much smaller than the characteristic size of the model domain, and when the relative permittivity of the layer is greater than the surrounding medium. When this boundary condition can be used, the resulting mesh size is much smaller, saving solution time and memory.
Application Library path: ACDC_Module/Capacitive_Devices/dielectric_shielding_comparison
Modeling Instructions
From the File menu, choose New.
New
In the New window, click  Model Wizard.
Model Wizard
1
In the Model Wizard window, click  2D.
2
In the Select Physics tree, select AC/DC>Electric Fields and Currents>Electrostatics (es).
3
Click Add.
4
Click  Study.
5
In the Select Study tree, select General Studies>Stationary.
6
Geometry 1
1
In the Model Builder window, under Component 1 (comp1) click Geometry 1.
2
In the Settings window for Geometry, locate the Units section.
3
From the Length unit list, choose cm.
Global Definitions
Parameters 1
1
In the Model Builder window, under Global Definitions click Parameters 1.
2
In the Settings window for Parameters, locate the Parameters section.
3
Geometry 1
Rectangle 1 (r1)
1
In the Geometry toolbar, click  Rectangle.
2
In the Settings window for Rectangle, locate the Size and Shape section.
3
In the Width text field, type 8.
4
In the Height text field, type 10.
5
Locate the Position section. In the x text field, type 0.1.
6
In the y text field, type -5.
Rectangle 2 (r2)
1
In the Geometry toolbar, click  Rectangle.
2
In the Settings window for Rectangle, locate the Size and Shape section.
3
In the Width text field, type 3.5.
4
Locate the Position section. In the x text field, type 0.1.
5
In the y text field, type 2.
Fillet 1 (fil1)
1
In the Geometry toolbar, click  Fillet.
2
On the object r2, select Points 2 and 3 only.
3
In the Settings window for Fillet, locate the Radius section.
4
In the Radius text field, type 0.5.
Copy 1 (copy1)
1
In the Geometry toolbar, click  Transforms and choose Copy.
2
3
In the Settings window for Copy, locate the Displacement section.
4
In the y text field, type -5.
Mirror 1 (mir1)
1
In the Geometry toolbar, click  Transforms and choose Mirror.
2
Click in the Graphics window and then press Ctrl+A to select all objects.
3
In the Settings window for Mirror, locate the Input section.
4
Select the Keep input objects check box.
5
Click  Build Selected.
6
Click the  Zoom Extents button in the Graphics toolbar.
Circle 1 (c1)
1
In the Geometry toolbar, click  Circle.
2
In the Settings window for Circle, locate the Size and Shape section.
3
In the Radius text field, type 0.95.
4
In the Sector angle text field, type 180.
5
Locate the Position section. In the x text field, type 0.1.
6
Locate the Rotation Angle section. In the Rotation text field, type -90.
Circle 2 (c2)
1
In the Geometry toolbar, click  Circle.
2
In the Settings window for Circle, locate the Size and Shape section.
3
In the Sector angle text field, type 180.
4
Locate the Position section. In the x text field, type -0.1.
5
Locate the Rotation Angle section. In the Rotation text field, type 90.
6
Click to expand the Layers section. In the table, enter the following settings:
7
Click  Build All Objects.
The geometry on the left side describes the full fidelity model. The geometry on the right side replaces the thin layer with a boundary in order to use the Dielectric Shielding feature.
Definitions
Create a set of selections to use when setting up the physics. First, create a selection for the wall of the inclusion in the full fidelity model.
Full fidelity
1
In the Definitions toolbar, click  Explicit.
2
3
Right-click Explicit 1 and choose Rename.
4
In the Rename Explicit dialog box, type Full fidelity in the New label text field.
5
Add a selection for the dielectric shielding boundaries.
Dielectric shielding
1
In the Definitions toolbar, click  Explicit.
2
In the Settings window for Explicit, locate the Input Entities section.
3
From the Geometric entity level list, choose Boundary.
4
5
Right-click Explicit 2 and choose Rename.
6
In the Rename Explicit dialog box, type Dielectric shielding in the New label text field.
7
Add a selection for the bulk area. This is the modeling domain for the Electrostatics interface.
Model domain
1
In the Definitions toolbar, click  Explicit.
2
3
Right-click Explicit 3 and choose Rename.
4
In the Rename Explicit dialog box, type Model domain in the New label text field.
5
Electrostatics (es)
1
In the Settings window for Electrostatics, locate the Domain Selection section.
2
From the Selection list, choose Model domain.
Ground 1
1
Right-click Component 1 (comp1)>Electrostatics (es) and choose Ground.
2
Ground 2
1
In the Physics toolbar, click  Boundaries and choose Ground.
2
Terminal 1
1
In the Physics toolbar, click  Boundaries and choose Terminal.
2
3
In the Settings window for Terminal, locate the Terminal section.
4
From the Terminal type list, choose Voltage.
5
In the V0 text field, type V0.
Terminal 2
1
In the Physics toolbar, click  Boundaries and choose Terminal.
2
3
In the Settings window for Terminal, locate the Terminal section.
4
From the Terminal type list, choose Voltage.
5
In the V0 text field, type V0.
Dielectric Shielding 1
1
In the Physics toolbar, click  Boundaries and choose Dielectric Shielding.
2
In the Settings window for Dielectric Shielding, locate the Boundary Selection section.
3
From the Selection list, choose Dielectric shielding.
4
Locate the Electric Shielding section. In the ds text field, type 1[mm].
Materials
Material 1 (mat1)
1
In the Model Builder window, under Component 1 (comp1) right-click Materials and choose Blank Material.
2
In the Settings window for Material, locate the Geometric Entity Selection section.
3
From the Selection list, choose Model domain.
4
Locate the Material Contents section. In the table, enter the following settings:
Material 2 (mat2)
1
Right-click Materials and choose Blank Material.
2
In the Settings window for Material, locate the Geometric Entity Selection section.
3
From the Selection list, choose Full fidelity.
4
Locate the Material Contents section. In the table, enter the following settings:
Material 3 (mat3)
1
Right-click Materials and choose Blank Material.
2
In the Settings window for Material, locate the Geometric Entity Selection section.
3
From the Geometric entity level list, choose Boundary.
4
From the Selection list, choose Dielectric shielding.
5
Locate the Material Contents section. In the table, enter the following settings:
Mesh 1
In the Model Builder window, under Component 1 (comp1) right-click Mesh 1 and choose Build All.
Study 1
In the Home toolbar, click  Compute.
Results
Electric Potential (es)
The default plot shows the surface plot of the electric potential. Change the expression to show the norm of the electric field.
Surface 1
1
In the Model Builder window, expand the Electric Potential (es) node, then click Surface 1.
2
In the Settings window for Surface, click Replace Expression in the upper-right corner of the Expression section. From the menu, choose Component 1 (comp1)>Electrostatics>Electric>es.normE - Electric field norm - V/m.
3
Locate the Coloring and Style section. From the Color table list, choose GrayPrint.
4
Clear the Color legend check box.
5
Select the Reverse color table check box.
Electric Potential (es)
Next, add a contour plot showing the electric potential.
Contour 1
1
In the Model Builder window, right-click Electric Potential (es) and choose Contour.
2
In the Settings window for Contour, locate the Levels section.
3
In the Total levels text field, type 21.
Color Expression 1
1
Right-click Contour 1 and choose Color Expression.
2
In the Settings window for Color Expression, click Replace Expression in the upper-right corner of the Expression section. From the menu, choose Component 1 (comp1)>Electrostatics>Electric>es.normE - Electric field norm - V/m.
Electric Potential (es)
Then, add a streamline plot of the electric field.
Streamline 1
1
In the Model Builder window, right-click Electric Potential (es) and choose Streamline.
2
3
In the Settings window for Streamline, locate the Streamline Positioning section.
4
In the Number text field, type 40.
Color Expression 1
1
Right-click Streamline 1 and choose Color Expression.
2
In the Settings window for Color Expression, click Replace Expression in the upper-right corner of the Expression section. From the menu, choose Component 1 (comp1)>Electrostatics>Electric>es.normE - Electric field norm - V/m.
3
Locate the Coloring and Style section. Clear the Color legend check box.
4
Click the  Zoom Extents button in the Graphics toolbar.
Compare the plot with Figure 2.
Finish the result analysis by evaluating the capacitance of the system.
Global Evaluation 1
1
In the Results toolbar, click  Global Evaluation.
2
In the Settings window for Global Evaluation, locate the Expressions section.
3
4
Click  Evaluate.
Global Evaluation 2
1
In the Results toolbar, click  Global Evaluation.
2
In the Settings window for Global Evaluation, locate the Expressions section.
3
4
Click Evaluate>Table 1 - Global Evaluation 1 (es.Q0_1/V0).
The capacitance should be about 13 pF in both cases.