This section is available when a temperature-dependent density defined in a material is used. On the material frame, the density is evaluated in relation to a reference temperature in order to ensure conservation of the mass in the presence of temperature variations. By default the Common model input is used. This corresponds to the variable
minput.Tempref, which is set to 293.15 K by default. To edit it, click the
Go to Source button (
), and in the
Default Model Inputs node under
Global Definitions, set a value for the
Volume reference temperature in the
Expression for remaining selection section.
The other options are User defined and all temperature variables from the physics interfaces included in the model.
This section is available when material properties are temperature-dependent. By default, the temperature of the parent interface is used and the section is not editable. To edit the Temperature field, click
Make All Model Inputs Editable (
). The available options are
User defined (default),
Common model input (the
minput.T variable, set to 293.15 K by default) and all temperature variables from the physics interfaces included in the model. To edit the
minput.T variable, click the
Go to Source button (
), and in the
Default Model Inputs node under
Global Definitions, set a value for the
Temperature in the
Expression for remaining selection section.
The default Thermal conductivity k uses values
From material. For
User defined select
Isotropic,
Diagonal,
Symmetric, or
Full based on the characteristics of the thermal conductivity and enter another value or expression in the field or matrix.
The default Density ρ and
Heat capacity at constant pressure Cp are taken
From material. See
Material Density in Features Defined in the Material Frame if a temperature-dependent density should be set.
For User defined enter other values or expressions.