Pressure Point Constraint
The Pressure Point Constraint condition can be used to specify the pressure level. If it is not possible to specify the pressure level using a boundary condition, the pressure level must be set in some other way, for example, by specifying a fixed pressure at a point.
Pressure Constraint
The relative pressure value is set by specifying the Pressure p0. Or, if the reference pressure pref defined at the physics interface level is equal to zero, p0 represents the absolute pressure.
When Include gravity is selected and Use reduced pressure not selected in the interface Physical model section, the Compensate for hydrostatic pressure approximation (named Compensate for hydrostatic pressure for compressible flows) check box is available and selected by default. When it is selected, the hydrostatic pressure is automatically added to the pressure entered in p0 user input.
Constraint Settings
This section is displayed by clicking the Show button () and selecting Advanced Physics Options.