•
|
For a DC-source, the Voltage Vsrc (default value: 1 V). DC-sources are active in Stationary and Time-Dependent studies.
|
•
|
For an AC-source: the Voltage Vsrc (default value: 1 V) and the Phase Θ (default value: 0 rad). AC-sources are active in Frequency Domain studies only.
|
•
|
For a sine source: the Voltage Vsrc (default value: 1 V), the Offset Voff (default value: 0 V), the Frequency (default value: 1 kHz), and the Phase Θ (default value: 0 rad). The sine sources are active in Time-Dependent studies and also in Stationary studies, providing that a value for t has been provided as a model parameter or global variable.
|
•
|
For a pulse source: the Voltage Vsrc (default value: 1 V), the Offset Voff (default value: 0 V), the Delay td (default value: 0s), the Rise time tr and Fall time tf (default values: 0 s), the Pulse width pw (default value: 1 μs), and the Period Tper (default value: 2 μs). The pulse sources are active in Time-Dependent studies and also in Stationary studies, providing that a value for t has been provided as a model parameter or global variable.
|
For the AC source, the frequency is a global input set by the solver. AC sources should be used in Frequency-domain studies only. Do not use the Sine source unless the model is time-dependent.
|