Thermal Expansion (Attachment)
Add the Thermal Expansion subnode to prescribe a deformation of the attachment caused by changes in temperature. This makes it possible to reduce stresses caused by the attachment being rigid, while there are thermal deformations in the flexible body to which it is attached.
The thermal strain depends on the coefficient of thermal expansion α, the temperature T, and the strain-free reference temperature Tref as
Thermal Expansion Properties
Specify the thermal properties that define the thermal strain in the attachment.
Select Inherit from domain to take the thermal expansion data from the domain to which it is attached. This should only be used when:
When Inherit from domain is not selected, enter:
A value or expression for Temperature T, specifying the temperature distribution of the attachment. Any spatial variation must be an explicit function of the material frame coordinates. It is not possible to use a computed temperature distribution.
The Coefficient of thermal expansion α. As a default, values From material are used. This requires that a material has been assigned to the boundaries of the attachment selection.
For User defined select Isotropic, Diagonal, or Symmetric to enter one or more components for a general coefficient of thermal expansion tensor α. When a nonisotropic coefficient of thermal expansion is used, the axis orientations are given by the coordinate system selected in the Coordinate System Selection section.
A value or expression for the Volume reference Temperature Tref which is the temperature at which there are no thermal displacements in the attachment.
Location in User Interface
Context Menus
Ribbon
Physics tab with Attachment node selected in the model tree: