The Distributed Capacitance node adds a distributed capacitance boundary condition according to the following equations for exterior boundaries (left) and interior boundaries (right):
Enter the values or expressions for Relative permittivity εr (dimensionless),
Surface thickness ds (SI unit: m), and
Reference potential Vref. The default value for the surface thickness is
10−3 m (1 mm) and 0 V for the reference potential.
Enter a value for the Contact work function Φc(SI unit: V). The default is 4 V.