Outlet
This condition should be used on boundaries for which there is a net outflow from the domain. To obtain a numerically well-posed problem, it is advisable to also consider the Inlet conditions when specifying an Outlet condition. For example, if the velocity is specified at the inlet, the pressure may be specified at the outlet, and vice versa. Specifying the velocity vector at both the inlet and the outlet may cause convergence difficulties. Selecting appropriate outlet conditions for the Navier-Stokes equations is a nontrivial task. Generally, if there is something interesting happening at an outflow boundary, the computational domain should be extended to include this phenomenon.
Boundary Condition
The available Boundary condition options for an outlet are Pressure, Fully developed flow, and Velocity.
Pressure Conditions
This option specifies the normal stress, which in most cases is approximately equal to the pressure. The tangential stress component is set to zero. If the reference pressure pref, defined at the physics interface level, is equal to 0, the value of the Pressure p0, at the boundary, is the absolute pressure. Otherwise, p0 is the relative pressure at the boundary.
The Normal flow option changes the no tangential stress condition to a no tangential velocity condition. This forces the flow to exit (or enter) the domain perpendicularly to the outlet boundary.
The Suppress backflow check box is selected by default. This option adjusts the outlet pressure in order to prevent fluid from entering the domain through the boundary.
Velocity
See the Inlet node Velocity section for the settings.
Fully Developed Flow
This boundary condition is applicable when the flow exits the domain into a long pipe or channel, at the end of which a flow profile is fully developed.
The channel can be thought of as a virtual extrusion of the outlet cross section. The outlet boundary must hence be flat in order for the fully developed flow condition to work properly. In 2D axisymmetric models, the outlet normal must be parallel to the symmetry axis.
Select an option to control the flow rate at the outlet:
Flow rate, V0. Two-dimensional models also require an Entrance thickness, Dz, which is the out-of-plane thickness of the extruded entrance channel.
Average pressure, Pav. Observe that Pav is the average pressure on the outflow.
The fully developed flow condition requires any volume force to be approximately aligned with the normal of the outlet boundary. A fully developed flow boundary cannot be adjacent to any Interior Wall feature.
Constraint Settings
This section is displayed by clicking the Show button () and selecting Advanced Physics Options.