Moisture Content
Use this node to specify the moisture conditions (relative humidity and temperature, or vapor concentration) on exterior boundaries.
Pair Selection
If this node is selected from the Pairs menu, choose the pair on which to apply this condition. A pair has to be created first. See Identity and Contact Pairs in the COMSOL Multiphysics Reference Manual for more details.
Moisture Content
When Specify is set to Relative humidity, the equation for this condition is
where and T0 are the prescribed relative humidity and temperature on the boundary. For User Defined, enter values or expressions. Else, select any available input (like Ambient temperature defined in an Ambient Properties node under Definitions).
Alternatively, choose Vapor concentration in the Specify list and set directly the Vapor concentration c0.
Constraint Settings
To display this section, click the Show More Options buttonĀ () and select Advanced Physics Options. Select the Use weak constraints check box to replace the standard constraints with a weak implementation.
Heat and Moisture Transport in a Semi-Infinite Wall: Application Library path Heat_Transfer_Module/Verification_Examples/semi_infinite_wall
Location in User Interface
Context Menus
Ribbon
Physics Tab with interface as Moisture Transport in Air or Moisture Transport in Building Materials selected: