This is a utility node that makes it possible to access intermediate solution results. By default, the software only stores the solution at the last computed node of a solver configuration. Add a Solution Store nodeĀ (
) anywhere in a solver configuration to make the COMSOL software store the solution at that point of the sequence in addition to the solution at the last computed node. You can use the solution from a
Solution Store node when analyzing the results and as initial values (via a study-type node) for other computations. By default, Solution Store nodes created under a
Parametric Solutions node (
) get a name that shows the values of the parameters used for the solution of a parametric sweep (for example,
Tinit=340, c0_pro=1400).
The Settings window for the Solution Store nodes contains the following sections: