The Stationary with Initialization (
) study is used for stationary turbulent flow models that require an initialization. It adds a
Wall Distance Initialization study step followed by a
Stationary study step to the Study node. The
Wall Distance Initialization study step is dedicated to solving for the reciprocal wall distance (that is, the reciprocal distance to the closest wall). The second step is an ordinary
Stationary study step, but it excludes the reciprocal wall distance except when the physics is put on a moving frame, in which case the reciprocal wall distance is solved for in the stationary step as well.
The Time Dependent with Initialization (
) study is used for time-dependent turbulent flow models that require an initialization. It adds a
Wall Distance Initialization study step followed by an ordinary
Time Dependent study step to the Study node. The
Wall Distance Initialization study step is dedicated to solving for the reciprocal wall distance, that is, the reciprocal distance to the closest wall.
The Wall Distance Initialization (
) study step is added to the
Stationary with Initialization and Time Dependent with Initialization studies when using a turbulent model. This first step is dedicated to solving for the reciprocal wall distance. For turbulence models, the distance determined in the initialization step is the distance to the closest wall. For two-phase flow it is the distance to the phase interface. The settings for this study are the same as for the
Stationary and
Time Dependent studies.