The default value in the Repair tolerance list is Automatic, which for 3D objects represented using the CAD kernel determines the repair tolerance internally. For 3D objects represented using the COMSOL kernel, and for 2D and 1D objects, Automatic means a relative repair tolerance of 10−6.
|
•
|
Choose Relative to enter a value for the Relative repair tolerance field (the default is determined by the main Geometry node’s setting). This value is relative to the largest absolute value of the coordinates of all input objects.
|
•
|
Choose Absolute to enter a value for the Absolute repair tolerance field (the default is determined by the main Geometry node’s setting; SI unit: m). This value uses the same unit as the geometry sequence’s length unit.
|