manual | none
|
|||
on | off
|
|||
The color table to use when coloring is set to colortable. See Color Tables for a list of color tables.
|
|||
on | off
|
|||
on | off
|
|||
on | off
|
Whether to display labels next to the contour lines. Only applicable in 2D and if contourtype is lines.
|
||
lines | filled
|
|||
{1,0,0} or last used color.
|
|||
{1,0,0} or last used color.
|
|||
{1,0,0} or last used color.
|
|||
{1,0,0} or last used color.
|
|||
The dataset this feature refers to. From parent is only available in 1D.
|
|||
The description of the expression in expr. Is used in the automatic title.
|
|||
on | off
|
|||
on | off
|
Whether the expression should be linearized at the linearization point. Applicable only if evalmethod is harmonic.
|
||
on | off
|
|||
on | off
|
|||
logarithmic | linear
|
|||
on | off
|
|||
none | plot name
|
|||
Time corresponding to last selected solnum for transient levels.
|
The time to use, for transient levels. Available when data is not parent and the underlying data is transient.
|
||
frequencyx | frequencyy
|
|||
number | levels
|
|||
The index of the solution to use, per level, or interp, but only for transient solutions. Available when data is not parent and the underlying data has multiple solutions.
|
|||
The element refinement to use, if resolution is set to manual. Bear in mind that this is the refinement used for the base dataset, so the number of elements in the model can increase radically if the plot uses, for example, a revolve dataset.
|
|||
Controls the plot’s resolution. A finer setting results in a higher resolution by modifying the internally computed default refinement. Use custom to enter your own refinement in the refine property.
|
|||
The index of the solution to use. Available when data is not parent and the underlying data has multiple solutions.
|
|||
solnum | solutioninfo
|
|||
The time to use, for transient problems. Available when data is not parent and the underlying data is transient.
|
|||
manual | none
|
|||
on | off
|
|||
auto if the title contribution should be computed automatically, possibly using the group’s customization. custom if the title contribution should be computed automatically, but customized. manual if the manual title contribution should be used (the title property). none if no title contribution should be used.
|
|||
on | off
|
|||
The unit to use for the expression in expr. If the old unit is not valid when the expression changes, the unit property is reset to default.
|
|||
on | off
|