Open Boundary
Use the Open Boundary node to set up mass transport across boundaries where both convective inflow and outflow can occur. Use the node to specify an exterior species composition on parts of the boundary where fluid flows into the domain. A condition equivalent to the Outflow node applies to the parts of the boundary where fluid flows out of the domain. The direction of the flow across the boundary is typically calculated by a Fluid Flow interface and is entered as Model Inputs.
Exterior Composition
Enter a value or expression for the species composition. Select:
Mass fractions (the default) to enter mass fractions (ω0, ω1, for example)
Mole fractions to enter mole fractions (x0, ω1, for example)
Molar concentrations (SI unit: mol/m3) to enter molar concentrations (c0, ω1, for example)
Number densities (SI unit: 1/m3) to enter number densities (n0, ω1, for example) and to describe the number of particles per volume n0