Interior Sound Hard Boundary (Wall)
The
Interior Sound Hard Boundary (Wall)
node, found under the
Interior Conditions
submenu, adds the boundary condition for a sound hard boundary or wall on interior boundaries. The condition reads
The condition ensures that the total normal velocity is zero on both the up and down side of the boundary, while applying a slit on the pressure (the pressure is discontinuous across the boundary).