You are viewing the documentation for an older COMSOL version. The latest version is available here.
Harmonic Perturbation
The Harmonic Perturbation subnode is available at the global level from the context menu (right-click the Coil parent node) or from the Physics toolbar, Attributes menu. Use this feature to specify a harmonic perturbation for the coil excitation.
Coil
A harmonic perturbation can be specified only if the Coil excitation of the parent feature is Coil current or Coil voltage. In the first case, enter a Coil current Icoil (SI unit: A). The default is 1 A. In the second case, enter a Coil voltage Vcoil (SI unit: V). The default is 1 V.