Applied Moment (Rigid Domain)
Use the
Applied Moment
subnode to apply moments on a rigid domain. The moment that you specify is interpreted in the selected coordinate system.
Applied Moment
Enter values or expressions for the components of the
Applied
moment
.
•
For 3D components, this is the
x
,
y
, and
z
components for
M
.
•
For 2D components, this is for the applied moment around the
z
axis
M
z
.
•
You can add the
Phase
subnode to specify the phase of this load in a frequency domain analysis.
•
You can specify this load to be a
Harmonic Perturbation
in a frequency domain analysis.
•
You can assign this load to a load group. See
Load Cases
in the
Structural Mechanics Modeling
chapter.
Location in User Interface
Context Menus
Solid Mechanics>Rigid Domain>Applied Moment
Shell>Rigid Domain>Applied Moment
Layered
Shell>Rigid Domain>Applied Moment
Beam>Rigid Domain>Applied Moment
Multibody Dynamics>Rigid Domain>Applied Moment
Ribbon
Physics tab with
Rigid Domain
node selected in the model tree:
Attributes>Applied Moment