Use the Port node where electromagnetic energy enters or exits the model. A port can launch and absorb specific modes. Use the boundary condition to specify wave type ports. Ports support S-parameter calculations but can be used just for exciting the model. This node is not available with the Electromagnetic Waves, Transient interface.
•
|
Circular Port Reference Axis to determine a reference direction for the modes. This subnode is selected from the Points submenu when Circular is selected as the type of port.
|
•
|
Periodic Port Reference Point to uniquely determine reciprocal lattice vectors. This subnode is selected from the Points submenu when Periodic is selected as the type of port.
|
Enter a unique Port name. Only nonnegative integer numbers can be used as
Port name as it is used to define the elements of the S-parameter matrix and numeric port names are also required for port sweeps and Touchstone file export.
Select the Type of Port —
User defined,
Numeric,
Rectangular,
Coaxial,
Circular, or
Periodic.
Periodic ports are available in 3D and 2D.
Circular and
Coaxial ports are available in 3D and 2D axisymmetry.
Numeric ports require a
Boundary Mode Analysis study type. It should appear before the frequency domain study node in the study branch of the model tree. If more than one numeric port is needed, use one Boundary Mode Analysis node per port and assign each to the appropriate port. Then, it is best to add all the studies; Boundary Mode Analysis 1, Boundary Mode Analysis 2,..., Frequency Domain 1, manually.
Numeric ports are by default computed for the deformed mesh whereas other types of ports compute the mode shape using geometry information.
To set whether it is an inport or a listener port, select On or
Off from the
Wave excitation at this port list. If
On is selected, enter a
Port input power Pin (SI unit: W) or a
Deposited power Pdep (SI unit: W) if the
Enable active port feedback check box is marked. When a
Deposited power is specified, the input power is adjusted so that the power that is not reflected equals the specified
Deposited power. If
Enable active port feedback is marked this must be the only inport.
|
The Port Sweep Settings section in the Electromagnetic Waves, Frequency Domain interface cycles through the ports, computes the entire S-matrix and exports it to a Touchstone file. When using port sweeps, the local setting for Wave excitation at this port is overridden by the solver so only one port at a time is excited.
|
Select the Activate slit condition on interior port check box to use the
Port boundary condition on interior boundaries.
Then select a Slit type —
PEC-backed (the default) or
Domain-backed. The
PEC-backed type makes the port on interior boundaries perform as it does on exterior boundaries. The
Domain-backed type can be combined with perfectly matched layers to absorb the excited mode from a source port and other higher order modes.
Click Toggle Power Flow Direction button to define the power flow for the port. For an excited port, the power flow should point in to the excited domain and for a listener port the power flow should point out from the excited domain. The power flow direction is visualized with a red arrow on the port boundary in the Graphics window.
|
When the Slit type is set to Domain-backed, there must be no waves reflected from the domain backing the port. Thus, the backing domain must have homogeneous material and geometric properties and it should be truncated by a PML domain or a nonreflecting boundary condition.
|
|
|
Select the Analyze as a TEM field check box to add
Integration Line for Current and
Integration Line for Voltage subnodes. These subnodes are available from the context menu (right-click the Port parent node) or from the
Physics toolbar,
Attributes menu. Enter a
Characteristic impedance Zref (SI unit:
Ω). The default is 50
Ω. The characteristic impedance of a port is calculated using the ratio of the voltage and current and the mode field on a port boundary is scaled by the ratio between the characteristic impedance and
Zref.
.
The input is based on the Type of Port selected above —
User Defined,
Rectangular, Circular,
or
Periodic. No entry is required if
Numeric or
Coaxial are selected.
Set the Mode phase θin (SI unit: rad) for the port mode field. The default is 0 radians. For instance, if the inspected port mode field is polarized in the opposite direction compared to the expected direction, a
Mode phase of
π (enter
pi in the field) can be used for polarizing the mode field in the expected direction. Notice that a change of the
Mode phase, either on the exciting or the listener port, changes also the S-parameter coupling the exciting and the listener port. However, a change of the
Mode phase on the exciting port does not modify the reflection coefficient (normally denoted S11) associated with the exciting port.
For User defined specify the eigenmode of the incoming wave at the port. Even if
Wave excitation at this port is set to
Off, the mode field should represent the incoming wave that corresponds to the actual outgoing wave. The mode field can be entered with an arbitrary amplitude and is normalized internally.
•
|
Enter the components of the Electric mode field E0 (SI unit: V/m) or the Magnetic mode field H0 (SI unit: A/m). The entered expressions must be differentiable.
|
•
|
Enter the Propagation constant β (SI unit: rad/m). This is frequency dependent for all but TEM modes and a correct frequency-dependent expression must be used.
|
For Rectangular specify a unique rectangular mode.
For 3D components, select a Mode type —
Transverse electric (TE) or
Transverse magnetic (TM). Enter the
Mode number, for example, 10 for a TE
10 mode, or 11 for a TM
11 mode.
For 2D components, to excite the fundamental mode, select the mode type Transverse electromagnetic (TEM), since the rectangular port represents a parallel-plate waveguide port that can support a TEM mode. Only TE modes are possible when solving for the out-of-plane vector component, and only TM and TEM modes are possible when solving for the in-plane vector components. There is only a single mode number, which is selected from a list.
In 2D axisymmetry, Coaxial does not support nonzero azimuthal mode number. The
Azimuthal mode number in the
Physics interface should be defined as zero.
For Circular specify a unique circular mode.
•
|
Select a Mode type — Transverse electric (TE) or Transverse magnetic (TM).
|
For 3D components, enter the Mode number, for example, 11 for a TE
11 mode, or 01 for a TM
01 mode. When
Circular is selected as the type of port in 3D, the
Circular Port Reference Axis subnode is available from the context menu (right-click the parent node) or from the
Physics toolbar,
Attributes menu. It defines the orientation of fields on a port boundary.
For 2D axisymmetry components, select whether the Azimuthal mode number is defined in the
Physics interface or if it is
User defined. For
User defined define an integer constant or an integer parameter expression for the
Azimuthal mode number. Note that the absolute value of the
Azimuthal mode number must be less than 11.
For Periodic specify parameters for the mode field. When
Periodic is selected, the
Diffraction Order port subnode is available from the context menu (right-click the parent node) or from the
Physics toolbar,
Attributes menu.
Select a Input quantity —
Electric field or
Magnetic field and define the mode field amplitude for the incoming wave at the port. Even if
Wave excitation at this port is set to
Off, the mode field amplitude should represent the incoming wave that corresponds to the actual outgoing wave.
•
|
For 2D components and if the Input quantity is set to Electric field, define the Electric mode field amplitude. For example, for a TE wave set the x, y, and z components to 0, 0, 1. Similarly, if the Input quantity is set to Magnetic field, define the Magnetic mode field amplitude. For a TM wave set the x, y, and z components to 0, 0, and 1.
|
•
|
Define the Angle of incidence, if Wave excitation at this port is On.
|
For 3D components, if Wave excitation at this port is
On, define the
Elevation angle of incidence and
Azimuth angle of incidence. The
Elevation angle of incidence α1 and
Azimuth angle of incidence α2 are used in the relations
where k is the wave vector,
kparallel is the projection of
k onto the port,
kF is the k-vector for Floquet periodicity,
n is the outward unit normal vector to the boundary, and
is one of the normalized primitive unit cell vectors from the periodic structure defined from
Periodic Port Reference Point.
The Elevation angle of incidence α1 is the angle between
n and
k.
The Azimuth angle of incidence is the counterclockwise rotating angle from the primitive vector
a1 around the axis built with
Periodic Port Reference Point and
n.
For periodic ports with hexagonal port boundaries, the definition of the vector a1 is slightly different from the default definition. In this case, the unit cell is actually a rhomboid, with primitive vectors pointing in other directions than the side vectors of the hexagon. Thus, for a hexagonal periodic port, the vector
a1 is defined along one of the sides of the hexagon, and it is not one of the primitive vectors of the hexagonal point lattice. The
Azimuth angle of incidence α2 is still measured from the vector
a1, even though this vector now refers to a side vector of the hexagonal port boundary and not a primitive vector.
For 2D components define the Angle of incidence. The
Angle of incidence α is defined by the relation
where k is the projection of the wave vector in the
xy-plane,
n is the normalized normal vector to the boundary,
k is the magnitude of the projected wave vector in the
xy-plane, and
z is the unit vector in the
z direction.
|
The propagation directions for listener Periodic ports are deduced from the angle setting(s) for the source Periodic port and the refractive indices defined for the source and the listener ports. Thus, adding source Periodic ports with different propagation angles will give ambiguous propagation directions for the listener Periodic ports.
|
This section is only available for Periodic ports to provide parameter settings that are used when automatically adding
Diffraction Order subnodes to
Periodic ports.
•
|
Select the Include in automatic diffraction order calculation check box to add Diffraction Order subnodes to the selected Periodic port, when the Compute Diffraction Order button is clicked from the exciting Periodic port.
|
•
|
Define the Refractive index, real part at the boundary.
|
•
|
Define the Maximum frequency — From study (the default) or User defined. When From study is selected, the Maximum frequency is taken from the study step associated with the physics interface. For User defined, enter the maximum frequency fmax (SI unit: Hz). The default value is 0 Hz. If a single frequency is used, insert the frequency, or if a frequency sweep is performed, insert the maximum frequency of the sweep. This parameter is only available when Wave excitation at this port is On.
|
When all parameters are defined, click the Compute Diffraction Orders button from the exciting
Periodic port to automatically create
Diffraction Order ports as subnodes to all
Periodic ports having the
Include in automatic diffraction order calculation check box selected.
Set the Port Offset doffset (SI unit: m) for the de-embedded S-parameter calculation. The default is 0 m. The phase of the de-embedded S-parameters is adjusted from the calculated S-parameters with the propagation constant and the value of
doffset.
where m is the source port name, n is the listener port name, β is propagation constant, and d is offset distance from the port boundary.
The de-embedding functionality is triggered when doffset is set to a nonzero value. It is assumed that the domain between the port boundary and the boundary projected by the
doffset is straight, while maintaining a constant cross-sectional shape.
To display this section, click the Show button (
) and select
Advanced Physics Options. For information about the
Constraint Settings section, see
Constraint Settings in the