Incident Intensity (Radiation in Participating Medium and Radiation in Absorbing-Scattering Medium Interfaces)
Use this node to specify the radiative intensity along incident directions on a boundary. This intensity is a power per unit solid angle and unit surface area projected onto the plane normal to the radiation direction.
Pair Selection
If this node is selected from the Pairs menu, choose the pair on which to apply this condition. A pair has to be created first. See Identity and Contact Pairs in the COMSOL Multiphysics Reference Manual for more details.
Incident Intensity
The Boundary radiation intensity Iwall should be specified. This represents the value of radiative intensity along incoming discrete directions. Values of radiative intensity on outgoing discrete directions are not prescribed.
When Discrete ordinates method is selected, the components of each discrete ordinate vector can be used in this expression. The syntax is name.sx, name.sy, and name.sz, where name is the physics interface node name. By default, the Radiation in Participating Media interface is rpm so rpm.sx, rpm.sy, and rpm.sz correspond to the components of discrete ordinate vectors.
When P1 approximation is selected as the Radiation discretization method for the physics interface, there is additional theory, equations, and variables described in P1 Approximation Theory.
Location in User Interface
Context menus
Radiation in Participating Media>Incident Intensity
Radiation in Absorbing-Scattering Media>Incident Intensity
Radiation in Participating Media>Pairs>Incident Intensity
Radiation in Absorbing-Scattering Media>Pairs>Incident Intensity
Ribbon
Physics Tab with Radiation in Participating Media or Radiation in Absorbing-Scattering Media selected:
Boundaries>Incident Intensity
Pairs>Incident Intensity