Use this subnode to specify the temperature on the exterior side of a thin layer, a thin film, or a fracture. As a subfeature of Thin Layer, it is only applicable when
Layer type is set to
Thermally thick approximation or
General, on exterior boundaries. As a subfeature of
Thin Film and
Fracture, it is only applicable when
Layer type is set to
General, on exterior boundaries.
For User defined, enter a value or expression for the
Temperature T0. Else, select an
Ambient temperature defined in an
Ambient Thermal Properties node under
Definitions.
The equation for this condition is T = T0 where
T0 is the external temperature to be prescribed.
Physics Tab with Thin Layer,
Thin Film, or
Fracture selected in the model tree:
Attributes>External Temperature