Continuity on Interior Boundaries
Unless a boundary condition is specified on interior boundaries (such as a contact resistance condition), the COMSOL Multiphysics software ensures continuity in the field variables across interior boundaries. For assembly geometries with identity pairs, select a
Continuity
node in the
Pairs
menu in the boundary part of the context menu for most physics interfaces. The
Continuity
condition is only suitable for pairs where the boundaries match.
Boundary Selection
The selection list in this section shows the boundaries for the selected pairs.
Pair Selection
Select the pairs where you want to impose continuity across the pair boundaries. Select the pairs from the
Pairs
list (Ctrl-click to deselect).
Identity and Contact Pairs