No Slip
The
No Slip
sets up a no-slip condition for the flow on a hard wall:
Constraint Settings
To display this section, click the
Show
button (
) and select
Advanced Physics Options
.
Mechanical and thermal boundary conditions contribute with each other such that a condition can be set on the velocity and temperature simultaneously. Thermal type condition override each other and the same is true for mechanical type conditions.