A Point Load (on Axis) node can be added to points located at R = 0 in axially symmetric models. This is the only true point load an axisymmetric model, since loads applied at points having non-zero radial coordinates actually represent a Ring Load.
The Load list normally only contains User defined. When combining with another physics interface that can provide this type of load, it is also possible to choose a predefined load from this list.
•
You can add the Phase subnode to specify the phase of this load in a frequency domain analysis.