Use the Circular Wave Retarder node to define a circular wave retarder on a boundary selection. Add this node from the
Optical Devices submenu when
Intensity computation is set to
Compute intensity,
Compute intensity and power,
Compute intensity in graded media, or
Compute intensity and power in graded media in the physics interface
Intensity Computation section. The
Accumulator (Boundary) subnode is available from the context menu (right-click the parent node) or from the
Physics toolbar,
Attributes menu.
By default the Sense of rotation depends on ray trajectory check box is not selected. This means a positive value of the retardance always corresponds to clockwise rotation of the polarization ellipse. Select the check box then a positive value of the retardance corresponds to clockwise rotation of the polarization ellipse only when the ray crosses the boundary in the direction indicated by the normal vector in the Graphics window.
The Reverse sense of rotation check box is available when the
Sense of rotation depends on ray trajectory check box is selected. Click to select this check box to reverse the direction of the normal vector shown in the Graphics window.
This section is available if an Auxiliary Dependent Variable has been added to the model. The settings are the same as for the
Wall feature.