Periodic Boundary Conditions
The RF Module has a dedicated Periodic Condition. The periodic condition can identify simple mappings on plane source and destination boundaries of equal shape. The destination can also be rotated with respect to the source. There are three types of periodic conditions available (only the first two for transient analysis):
Continuity—The tangential components of the solution variables are equal on the source and destination.
Antiperiodicity—The tangential components have opposite signs.
Floquet periodicity—There is a phase shift between the tangential components. The phase shift is determined by a wave vector and the distance between the source and destination. Floquet periodicity is typically used for models involving plane waves interacting with periodic structures.
Periodic boundary conditions must have compatible meshes. This can be done automatically by enabling the Physics-control mesh in the setting for The Electromagnetic Waves, Frequency Domain Interface or by manually setting up the correct mesh sequence
For an example of how to use the Physics-controlled mesh, see Fresnel Equations: Application Library path RF_Module/Verification_Examples/fresnel_equations.
In the COMSOL Multiphysics Reference Manual: