Outlet
The Outlet node defines an edge or point where fluid leaves the gap.
Outlet Settings
Select an Outlet conditionZero pressure (the default), Pressure, or Normal outflow velocity.
For Zero pressure, pf = 0 applies on the boundary, edge, or point.
For Pressure, enter a Pressure pf0 (SI unit: Pa) to impose pf = pf0 on the boundary, edge, or point. The default is 0 Pa. If the reference pressure pref, defined at the physics interface level is 0, pf0 is the absolute pressure. Otherwise, pf0 is the relative pressure.
For Normal outflow velocity, enter a Normal outflow velocity U0 (SI unit: m/s). The default is 0 m/s.