Select the sequence to Run from the list. The default is to run
All solver configurations. Click the
Go to Source buttonĀ (
) to go to the source solver configuration.
Store a copy of the solution once it has run by selecting the Keep all solutions check box. The name of the copy is generated from the current sequence name and parameter values. The default is to clear previous solutions. To disable it, clear the
Clear previous check box. To add solver nodes to a solver configuration, right-click a
Solver node and then select a solver from the
Solvers submenu.
This section contains a table of parameters and solutions after running a batch job or a parametric sweep. In the Parameters column you find the parameters in the parametric sweep, for example, and the values for those parameters at that step in the sweep. The corresponding row of the
Solution column contains the name of the solution that corresponds to that set of parameter values. Typically,
Solution Store nodes store those solutions, which are also available from the
Solution list in the Solution data sets.