The Previous Solution node (
) is an optional attribute node of the
Parametric attribute node and the
Time-Dependent Solver node. It handles field variables that have to be accessed at a previous parameter value or time. In time-dependent studies, it can be useful for time-dependent contact problems with friction, for example.
Use the Variables list to specify which variables to associate with the previous parameter value or time step rather than the present one.
Use the Linear solver list to select a solver for the linear systems associated with the quantities specified by
Variables. The available solvers are of the types
Direct and