The arrow scaling: Proportional uses the actual arrow length, normalized a unit length, and logarithmic a length proportional to the logarithm of the arrow length.
|
|||
If arrowscalefactor is true: the length scale factor
|
|||
If true, arrowscale is used; otherwise the scale factor is computed automatically.
|
|||
manual | automatic
|
Whether to specify a manual absolute tolerance for the position. automatic indicates that the absolute tolerance for the position is the mean of the lengths of the bounding box of the geometry multiplied by the relative tolerance.
|
||
Vector of values from 0 to 1 to describe the start points. Active when bndmethod is set to coord. Available in 2D only.
|
|||
number | coord
|
Active when posmethod is set to bnd. Available in 2D only.
|
||
{1,0,0} or last used color.
|
|||
{1,0,0} or last used color.
|
|||
The description of the expressions in expr. Is used in the automatic title.
|
|||
on | off
|
|||
none | plot name
|
|||
Time corresponding to last selected solnum for transient levels.
|
The time to use, for transient levels. Available when data is not parent and the underlying data is transient.
|
||
double > 1
|
If arrowlength is logarithmic: The ratio between the maximum arrow length and the arrow length below which no arrow is drawn.
|
||
The index of the solution to use, per level, or interp, but only for transient solutions. Available when data is not parent and the underlying data has multiple solutions.
|
|||
The maximum number of steps to use in the particle simulation. Active when maxstepsactive is set to on.
|
|||
on | off
|
Whether to manually specify the maximum number of steps used in particle simulation. off indicates that the limit varies in this way: for static flow fields, the algorithm uses the value 1000; for time-dependent flows, there is no upper limit of the number of steps, and the particle simulation goes on until it reaches the end time.
|
||
disappear | stick
|
stick plots the points on the boundary at the exit point, and disappear does not render these points at all.
|
||
on | off
|
|||
on | off
|
|||
start | bnd
|
|||
The index of the solution to use. Available when data is not parent and the underlying data has multiple solutions.
|
|||
solnum | solutioninfo
|
|||
on | off
|
Only affects time-dependent problems. When set to on, this property freezes the time and considers this a static flow field.
|
||
The maximum time at which to end the particle-tracing simulation for static flow fields. Active when statictendactive is set to on.
|
|||
on | off
|
Whether to specify the end time for static flow fields automatically. (For time-dependent flows, the automatic end time is the last time that the time-dependent solver returns.) When set to off, there is no upper limit of the time. In this case, the particle simulation goes on until all particles exit the geometry or the simulation reaches the maximum number of steps.
|
||
automatic | manual
|
|||
The time to use, for transient problems. Available when data is not parent and the underlying data is transient.
|
|||
Active when pointtype is set to comettail and tailscaleactive is on. Specifies the manual scale factor with which the comet tail expression is multiplied.
|
|||
on | off
|
|||
on | off
|
|||
auto if the title contribution should be computed automatically, possibly using the group’s customization. custom if the title contribution should be computed automatically, but customized. manual if the manual title contribution should be used (the title property). none if no title contribution should be used.
|
|||
on | off
|
on indicates a manual start time (set in the tstart property). Off indicates that the start time becomes either the first time value that the time-dependent solver returns or 0 for stationary flows. Available when dropmethod is set to once or freq.
|
||
on | off
|
|||
on | off
|
|||
Absolute coordinates in the z-direction, active when posmethod is set to coord. Available in 3D only.
|