Inflow
The Inflow node adds a boundary condition for an inflow boundary, where the concentration for all species is specified in the manner of .
This condition is identical to the Concentration node, but is applied to all species and cannot be applied to individual species.
Concentration
Specify the concentration ci (SI unit: mol/m3) of each species individually by entering a value or expression in the corresponding field.
Boundary Condition Type
The Concentration constraint is selected by default. This setting constrains the concentration values on the boundary by the use of point-wise constraints. Flux (Danckwerts) can be advantageous when high reaction rates are anticipated in the vicinity to the inlet. This uses a flux boundary condition based on the velocity across the boundary and the concentration values.
Constraint Settings
To display this section, click the Show button () and select Advanced Physics Options.