The Acoustic-Solid Interaction, Transient interface (
), found under the
Acoustics>Acoustic-Structure Interaction branch (
) when adding a physics interface, combines the Pressure Acoustics, Transient and Solid Mechanics interfaces to connect the acoustics pressure variations in the fluid domain with the structural deformation in the solid domain. It can, for example, be used to determine the transmission of sound through an elastic structure or solve for the coupled vibroacoustics phenomena present in a loudspeaker.
When a predefined Acoustic-Solid Interaction, Transient interface is added from the
Acoustics>Acoustic-Structure Interaction branch of the
Model Wizard or
the Add Physics windows, the
Pressure Acoustics, Transient and
Solid Mechanics interfaces are added to the Model Builder.
In addition, the Multiphysics node is added, which automatically includes the multiphysics coupling feature
Acoustic-Structure Boundary.
When physics interfaces are added using the predefined coupling features the Selection on the coupling feature is automatically set to
All boundaries. In this way the multiphysics coupling is automatically active on all boundaries with
Pressure Acoustics, Transient on one side and
Solid Mechanics on the other.
For example, if the single interfaces are added, COMSOL Multiphysics adds an empty Multiphysics node. You can choose the available coupling features, but you need manually to select on which boundaries they need to be applied, or select
All boundaries to recover the predefined behavior.
Physics nodes are available from the Physics ribbon toolbar (Windows users),
Physics context menu (Mac or Linux users), or right-click to access the context menu (all users).