Lumped Element
Use a Lumped Element node to mimic the insertion of a resistor, capacitor, inductor or general impedance between two metallic boundaries. It is similar to the Lumped Port but does not allow for an excitation and does not generate S-parameter output.
Lumped Element Properties
Enter a unique Lumped element name. See Lumped Port for the rest of the settings.
Settings
Select a Lumped element typeUser defined (the default), Inductor, or Capacitor.
For User defined enter a Lumped element impedance Zelement (SI unit: Ω; default 50 Ω.)
For Inductor enter a Lumped element inductance Lelement (SI unit: H; default 1 nH).
For Capacitor enter a Lumped element capacitance Celement (SI unit: F; default 1 pF).