The Electrostatics Interface and The Electrostatics, Boundary Elements Interface can also be coupled by using the same name for the dependent variable for both interfaces. Then Boundary Electric Potential Coupling is not needed. How to set the name for the dependent variable is described in the Dependent Variables section.
|
When using The Electrostatics, Boundary Elements Interface with iterative solvers, Right Preconditioning is preferred. Thus, it is advised to check that Right Preconditioning is used when combining the Boundary Electric Potential Coupling with The Electrostatics, Boundary Elements Interface and other physics interfaces. How to define Right Preconditioning is described in Iterative in the COMSOL Multiphysics Reference Manual.
|